Magnetic particle testing (MT) is a popular, low-cost method used to perform nondestructive testing (NDT) of ferromagnetic material. Ferromagnetic is defined in ASME Boiler and Pressure Vessel Code Section V as “a term applied to materials that can be magnetized or strongly attracted by a magnetic field.” MT is an NDT method that checks for surface discontinuities but can also reveal discontinuities slightly below the surface.

How Magnetic Particle Testing Works

When ferromagnetic material (typically iron or steel) is defect free, it will transfer lines of magnetic flux (field) through the material without any interruption.

But when a crack or other discontinuity is present, the magnetic flux leaks out of the material. As it leaks, magnetic flux (magnetic field) will collect ferromagnetic particles (iron powder), making the size and shape of the discontinuity easily visible.

However, the magnetic flux will only leak out of the material if the discontinuity is generally perpendicular to its flow. If the discontinuity, such as a crack, is parallel to the lines of magnetic flux, there will be no leakage and therefore no indication observed. To resolve this issue, each area needs to be examined twice. The second examination needs to be perpendicular to the first so discontinuities in any direction are detected. The NDT technician must ensure that enough overlap of the areas of magnetic flux is maintained throughout the examination process so discontinuities are not missed.

History of Magnetic Particle Examination

Magnetism was first used as early as 1868 to check for cannon barrel defects. Cannon barrels were first magnetized, and then a magnetic compass was moved down the length of the barrel. If a discontinuity was present, the magnetic flux would leak out and cause the compass needle to move. Defects could be easily located with this technique.

In the early 1920s, William Hoke noticed metallic grindings from hard steel parts (held by a magnetic chuck while being ground) formed patterns that followed the cracks in the surface of parts he was machining. He also found that by applying fine ferromagnetic powder to the parts, there was a buildup of powder at the discontinuities that formed a more visible indication.

By the 1930s, MT was quickly replacing the oil and whiting method of NDT [liquid penetrant testing (PT)] in the railroad industry. It was quicker and did not leave behind the white powder that required cleanup. After an MT evaluation, only iron powder was left behind, which could easily fall off the part or be blown away.

Different Techniques

There are many different techniques and combinations of techniques of MT. The ASME Boiler and Pressure Vessel Code, Section V, Article 7, recognizes five different techniques of magnetization:

1. Prod technique.

2. Longitudinal magnetization technique.

3. Circular magnetization technique.

4. Yoke technique.

5. Multidirectional magnetization technique..

There are two different ferromagnetic examination media: dry particles and wet particles. Both forms can be either fluorescent or nonfluorescent (visible, color contrast) and come in a variety of colors to contrast with the tested material.

Most-Used Methods

Two of the most-used methods are the stationary horizontal system, using longitudinal and circular magnetization techniques, and the portable yoke technique.

Stationary systems are generally used for smaller parts such as crank shafts and valve stems. They are often found indoors around machine shops and heat-treating facilities. Typically, they have a headstock and tailstock. Parts can be clamped between stocks for magnetization. There is also a coil placed around the part to magnetize it in the perpendicular direction. Stationary horizontal systems use the wet particle technique with a circulation tank below the equipment. Wet particles flow over the examined part and drain into the circulation tank. Wet particles have more mobility flowing in a liquid than do dry particles. This mobility helps sensitivity by allowing particles to easily move to the discontinuities. Fluorescent particles are commonly used with stationary horizontal systems because indoor operation makes it easy to darken the area; required ultraviolet (black) light can then be used to evaluate the parts. Both wet method examinations have about the same sensitivity, but under correct lighting conditions, fluorescent indications are much easier to see. This type of stationary system can cost $15,000 or more.

The MT yoke technique is the most portable and lowest-cost method, and therefore the most popular. A typical yoke kit would cost around $750. Most yokes can operate in alternating current (AC) or direct current (DC) modes. DC gives the most penetration and is recommended if subsurface discontinuities need to be detected. AC is recommended if the surface is rough, because AC gives the particles more mobility than DC. A yoke has an electric coil in the unit, creating a longitudinal magnetic field that transfers through the legs to the examined part. The yoke technique is easy to use with minimal training. It can be used indoors, outdoors, inside vessels and tanks, and in all positions. Prior to use, the magnetizing power of the electromagnetic yoke shall have been checked within the past year. An AC yoke must have a lifting power of at least 10 lb and a DC yoke of at least 40 lb.

Basic Steps

The following illustrate steps to use with the dry powder, nonfluorescent, yoke technique. Prior to the start of examination, all equipment and meters shall be calibrated.

1. Clean the surface to be examined. This may be accomplished using detergents, organic solvents, descaling solutions, paint removers, vapor degreasing, sand or grit blasting, or ultrasonic cleaning methods.

2. Introduce a magnetic field into the part.

3. Apply the ferromagnetic medium while the part is still magnetized.

4. Remove excess ferromagnetic medium with a light air stream from a bulb, syringe, or other source of low-pressure dry air.

5. Interpret and evaluate any indications to the applicable acceptance standard.

6. Turn the yoke 90 deg from the original position and repeat steps 2–5. Clean and demagnetize if necessary.

Many standards require the magnetic particle visible method (color contrast) be evaluated with a minimum light intensity of 100 footcandles on the part surface. The proper quantity of light must be verified using some type of calibrated light meter and witnessed and accepted by the NDT technician. If fluorescent magnetic particles are being used, a black light shall achieve a minimum of 1000 microwatts per square centimeter on the examined surface. If alternate wavelength light sources are used to provide ultraviolet light, causing fluorescence in the particles, it shall be qualified in accordance with ASME Section V, Article 7, Appendix IV.

Typical Examples of ASME Code-Required NDT Examinations

In the ASME codes of construction, magnetic particle examination or liquid penetrant examination is specified many times to detect the possibility of surface defects. If material is nonmagnetic, the only choice is liquid penetrant examination. However, if material is ferromagnetic, magnetic particle examination is generally used. Some typical examples of ASME code-required inspections include, but are not limited to,

• Castings for surface defects.

• Plates for laminations in corner joints when the edge of one plate is exposed and not fused into the weld joint.

• Head spin hole plug welds.

• Weld metal buildup on plates.

• Areas where defects have been removed before weld repair.

Once boilers and pressure vessels are in service, MT can be a widely used examination method. The National Board Inspection Code (NBIC) specifies MT may be used for the inspection of items such as:

• Internal and external surfaces of boilers and pressure vessels.

• Vessels in liquid ammonia service.

• Components subjected to fire damage.

• Locomotive and historical boilers.

• Yankee dryers.

• Cargo tanks.

• Vessels in LP gas service.

• Weld repairs and alterations to pressure-retaining items.

Advantages and Disadvantages of Magnetic Particle Examination

Advantages

• Can detect both surface and nearsurface indications.

• Surface preparation is not as critical as with other NDT methods. Most surface contaminants will not hinder detection of a discontinuity.

• A relatively fast method of examination.

• Indications are visible directly on the surface.

• Low-cost compared to many other NDT methods.

• A portable NDT method, especially when used with battery-powered yoke equipment.

• Post cleaning generally not necessary.

• A relatively safe technique; materials generally not combustible or hazardous.

• Indications can show relative size and shape of the discontinuity.

• Easy to use and requires minimal amount of training.

Disadvantages

• Nonferrous materials, such as aluminum, magnesium, or most stainless steels, cannot be inspected.

• Examination of large parts may require use of equipment with special power requirements.

• May require removal of coating or plating to achieve desired sensitivity.

• Limited subsurface discontinuity detection capabilities.

• Post demagnetization is often necessary.

• Alignment between magnetic flux and indications is important.

• Each part needs to be examined in two different directions.

• Only small sections or small parts can be examined at one time.

In conclusion, magnetic particle testing can be a useful nondestructive testing method during new construction and in-service inspections. It can only be used on ferromagnetic materials; therefore, it is not the best method for all applications. For quick, low-cost inspections, MT is often the best NDT method for detecting surface and slightly subsurface discontinuities.